Manual ElDES ESIM264 v2.2 23
5. Conguration & Control
The system conguration and control can be performed by sending SMS messages to ESIM264 phone number, using EKB2 keyboard,
EKB3 keyboard, via USB connection locally or via GPRS connection remotely using ELDES Conguration Tool software, which is recom-
mended for quick and more convenient system conguration.
5.1 Primary System Conguration
1. Connect the main power supply and wait until PWR LED lights up.
2. The illuminated NETWORK LED indicates that the system su-
ccessfully registered to GSM network.
3. Find the best GSM antenna position by following NETWORK LED
indications in order to get the strongest GSM signal. Possible indi-
cations are mentioned in the table.
4. Set the language. See chapter 5.4.1 SMS Language for more details.
5. Change the default SMS password. See chapter 5.4.2 Passwords for
more details.
6. Set the phone number for User 1. See chapter 5.4.3 User Phone Numbers for more details.
After completing these steps the system is ready for further conguration.
If you fail to receive an SMS reply from the system, please, check the SMS centre phone number.
5.2 Ways of System Conguration
In order to congure and control the system using SMS message, send the text command to the ESIM264 system phone
number from one of the preset user phone numbers. The structure of SMS message consists of 4 digit SMS password (the
default SMS password is 0000 – four zeros), the parameter and value. For some parameters the value does not apply, i.e.
STATUS.
The system conguration and control with EKB2 keyboard is performed by navigating throughout the menu section list
displayed on LCD screen. To navigate in the menu path, touch ↓, ↑ keys to select the desired menu section and touch OK
key to open the selected section. To enter a required value, use 0... 9 keys and touch OK key for value conrmation or can-
cel/go one menu section back by touching ← key. The value can be typed in directly by touching 0... 9 keys while high-
lighting the desired menu section. EKB2 menu type is “circle”, therefore when the last section in the menu list is selected,
you will be brought back to the beginning of the list after touching the ↓ key. In this installation manual, the menu path
is provided under “tree” view by starting at main screen view. Valid parameter values and range are indicated in brackets.
NOTE: Menu section CONFIGURATION is secured with administrator password. The default administrator password is 1470.
NETWORK LED Indication GSM Signal Strength
OFF No GSM signal
Flashing every 3 sec. Poor
Flashing every 1 sec. Medium
Flashing several times per sec. Good
Solid ON Excellent
SMS
EKB2
SMS centre phone number is stored in a SIM card by the GSM operator, therefore if the
SIM card has already been successfully used to send SMS messages from a mobile phone,
then it is not necessary to change the SMS centre number.
Set SMS Centre
Phone Number
SMS text:
0000_SMS_+4411111111111
Example: 0000_SMS_+446545417732
ATTENTION! In this user manual the underscore symbol ”_” represents one space character. Every underscore symbol
must be replaced by a single space character. There must be no spaces or other unnecesary characters at the be ginning
and at the end of the message. XXXX – 4-digit SMS password (the default SMS password is 0000 – four zeros).